Page 5-42 MDE-4334D Atlas™ Start-up and Service Manual · July 2013
Electronic and Electrical Components Atlas 8800 Parts
ATC T-Meter Module PCA
Figure 5-34 shows the Hydraulic Interface that contains assemblies and components related to
customer information on T20092-G1 PCA. The AT
C T-Meter Module PCA Interface PCA
modifies the pulser-count to account for the ambient temperature change. The adjusted
pulser-count is supplied to the Pump Controller PCA.
Figure 5-34: ATC T-Meter Module PCA
PCA Connections and Cables
Connector # Through Cable To Assembly At Connector #
P200 (16) R20148-G3 Probe 2 PTP5 (16)
P201 (10) R20147-G1 T19428-G1 JIS (10)
P203 (16) R20148-G3 Probe 1 PTP5 (16)
Manager Keypad [T17549-G1 (Atlas 8800 Only)]
Figure 5-35 shows the Manager Keypad used in Atlas 8800 units to display pump transaction
information in two locations. The Manager Keyp
ad relates to T20092-G1 PCA, shown in
Figure 5-31 on page 5-38.
Figure 5-35: Manager Keypad [T17549-G1 (Atlas 8800 Only)]
PCA Connections and Cables
Connector # Through Cable To Assembly At Connector #
P901A (10) R19951-G1 T20092-G1 P203 (10)