MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006 Page 9
Installation
3 In the kit, locate the 218AY00 single intrinsic safety (IS) barrier and 212AY04 single probe
connector assembly. Remove the nut and washer from the mounting stud on the IS barrier and
slide them off the wires. Save for reuse.
4 Feed the wires extending from the IS barrier mounting stud through the hole in the shelf as
shown in Figure 4 and place the mounting stud through the hole.
Figure 4: Mounting the IS Barrier on the Shelf
5
Place the wires extending from the mounting stud through the mounting hole in the single
probe connector assembly and place the connector assembly up on the stud (underneath the
shelf).
6 Place the washer and nut over the wires and turn nut onto the stud securing the IS barrier and
probe connector. Tighten snugly but do not overtighten.
7 Place the wires extending from the top of the IS barrier up through the grommet in the upper
shelf as shown in Figure 5.
Note: Figure 5 shows two pairs of wires (for a twin unit installation). There is only one pair of
wires in this single unit installation.
IS Barrier
Probe Connector
Assembly
Notch in Shelf
If your kit contains the newer version of the 218Y00 IS Barrier (see Figure 1 for
identification) and your unit does NOT have the notch in the shelf (Figure 4), the IS
barrier will not mount. DO NOT try to mount the IS barrier if the shelf does not have
the notch.
CAUTION