Page 22 MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006
27 Remount the LP-70 Polycase box cover removed in step 1.
28 Using two of the crimp splices, connect the two green wires extending from the bottom of the
IS barrier mounting stud to the two green wires attached to the dual probe connector assembly.
29 Using two of the crimp splices, connect the two yellow wires extending from the bottom of the
IS barrier mounting stud to the two yellow wires attached to the dual probe connector
assembly.
30 In the kit, locate the following: (See Figure 1 for parts identity)
W199 probe assemblies (2)
BC407 Thermowells (2)
235-C Thermowell Plugs (2)
BC546 Adapters (2)
31 Underneath the shelf (where the IS barrier is mounted), locate the two plugs in the hydraulic
coupling toward the right side of the unit (Figure 21).
Figure 21: Probe Assembly Mounting Location
32
Using the appropriate size Allen wrench, remove the two plugs.
7 Pulser Adder ON for 9840
8 ATC ON for ATC ON, OFF for ATC OFF
DIP Switch Settings
Switch
Number Switch Function Settings
Plugs