Gasboy 03908X User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Installation
Page 14 MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006
28 Remount the LP-70 Polycase box cover removed in step 1.
29 Using two of the crimp splices, connect the two yellow wires extending from the bottom of the
IS barrier mounting stud to the two blue wires attached to the single probe connector assembly.
30 Using two OM0205 caps or suitable-size wire nuts (OM0205 caps or wire nuts are not part of
the kit.), cap the end of the two green wires extending from the bottom of the IS barrier.
31 In the kit, locate the following: (See Figure 1 for parts identity)
W199 probe assembly
BC407 Thermowell
235-C Thermowell Plug
BC546 Adapter
32 Underneath the shelf (where the IS barrier is mounted), locate the two plugs in the hydraulic
coupling (Figure 11).
Figure 11: Probe Assembly Mounting Location
33
Using the appropriate size Allen wrench, remove the two plugs.
4Not used
5 Pulser Multiplier ON for 9850, OFF for 9852/9853
6 Number of Probes ON for two (2) probes, OFF for one (1) probe
7 Pulser Adder ON for 9840
8 ATC ON for ATC ON, OFF for ATC OFF
DIP Switch Settings
Switch
Number Switch Function Settings
Plugs
Page view 13