MDE-4504 Site Controller II CPU/Memory Board/Program Upgrade Instructions · August 2005 Page 5
Updating Framos.Cfg Preparing to Upgrade
Note: If you are using the Standard Reports Package and are upgrading to 2.1x or above, you
must be running or upgrading to version 002 or above Standard Reports Package. See
“Reports Package Upgrade” on page 17.
For an SC II with two floppy disk drives
1 Move the old Release disk from the A: drive to the B: drive.
2 Install the new Release disk in the A: drive.
3 Type CP B:FRAMOS.CFG A:FRAMOS.CFG, and press ENTER.
4 Copy any user files from the old disk in the same manner.
5 Remove the old Release disk from the B: drive.
6 Place the new Applications disk in the B: drive.
For an SC II with a hard drive and a floppy disk drive
Note: The information given below is applicable only if you have been using the Reports
Package software.
1 Verify if a HARDBACK has been done as instructed in “Taking Backup” on page 3.
2 Insert the new Applications disk in the A: drive.
3 Type A:BIN/INSTALL, and press ENTER.
4 Type N if prompted to copy SYSBACK.DTA or OFFROAD.DTA.
5 At the prompt: Do you want to install from an additional floppy disk (Y/N):, insert the new
Release disk, type Y, and press ENTER.
6 If prompted, do not copy the new FRAMOS.CFG to the hard drive.
7 Use the CP command to copy user-created files and reports-related files from the C:/
PRESERVE directory to the proper directories on the hard drive and also to the new Release
disk in the A: drive.
8 Remove the disk from the A: drive.